Technical Specifications heater B600

Power rating, W.
600
Power consumed, Watt.
200
Voltage, V/Hz
230/50
Size, mm
1042/163/40
Weight, kg
4
Heating, m2 (main) to
6
Heating, m2 (additional)* up to
12
Installation height, m
2,4-3,0
Warranty, years
3

Purpose of the heater heater B600

Just turn on the infrared device and the room will become warm in a short time. It is recommended to use the B600 in rooms with a ceiling height of at least 2.2 and no more than 3 meters. The heater can be easily mounted on the ceiling or walls and can be used as additional or main heating. From 2021, the entire model range is black by default. The black BILUX know-how plate has 17% more heat transfer. Warranty: 3 years: the heater is installed by the buyer himself. 7 years: installation by certified specialists, without the use of additional voltage stabilization devices (voltage regulator or voltage relay). 25 years: installation by certified specialists with the use of additional voltage stabilization devices (voltage regulator or voltage relay).

Objects of use
  • Apartments, houses
  • Kindergartens, schools
  • Exhibition halls, shops
  • Separate rooms - balcony, loggia, hallway, shower sauna.

Heat calculation

Result

Bilux Power

1 574 W

The power of traditional heating

2 430 W

Any questions?

We recommend ordering the implementation of Bilux from our specialists

We have been implementing Bilux for 12 years, we have made a lot of mistakes and know what to do in difficult cases. If an inexperienced installer is involved in the installation, we cannot guarantee that the heater will operate at maximum efficiency.
During installation, the installers take into account the height of the ceilings, wall thickness and location of the windows, and ensure fire and electrical safety.

Do not install heaters yourself

Example. The workshop employees bought three of the most powerful ceiling heaters and installed them themselves at a height of 3 meters at the edges and in the middle of the room. It was still cold in the workshop.
When a specialist is involved in the implementation, he makes a heat calculation and selects the power and number of heaters, chooses the right places for installation.
In the workshop, it was necessary to hang five low-power heaters around the perimeter.
The specialist checks the heat losses and, if necessary, advises thermal insulation. In the workshop, it was necessary to insulate the floor.
The specialist takes into account the height of the ceilings and the proportions of the room. In the workshop, it was necessary to hang the heaters half a meter lower.